Dell Perc raid

Allikas: Kuutõrvaja

Dellr510h700.jpg

Raidikaarti integreeritud biosi vaade.

Dell Perc FreeBSD

mfi seade dmesgis

mfi0: <Dell PERC H700 Integrated> port 0xfc00-0xfcff mem 0xef0fc000-0xef0fffff,0xef040000-0xef07ffff irq 44 at device 0.0 on pci1

Kasutamiseks mfiutil

# mfiutil show drives
mfi0 Physical Drives:
 0 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVH6> SCSI-6 E1:S0
 1 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVN6> SCSI-6 E1:S1
 2 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CV7B> SCSI-6 E1:S2
 3 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CTYF> SCSI-6 E1:S3
 4 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVM4> SCSI-6 E1:S4
 5 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z29182GP> SCSI-6 E1:S5
 6 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVHG> SCSI-6 E1:S6
 7 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z2918395> SCSI-6 E1:S7

Mfiutiliit lubab kuumvahetatavaid kettaid jooksvalt raidi lisada. Näiteks oleme lisanud töötavale masinale kuus kõvaketast ja tahame tekitada neile raid10 seadistuse

# mfiutil create raid10 E1:S2,E1:S3 E1:S4,E1:S5 E1:S6,E1:S7

Dmesgist saame vaadata, et kõik läks korrektselt ja seade tekkis

mfid1: <MFI Logical Disk> on mfi0
mfid1: 1715328MB (3512991744 sectors) RAID volume  is optimal

Või siis küsida staatust kontrollerist endast

# mfiutil show volumes
mfi0 Volumes:
  Id     Size    Level   Stripe  State   Cache   Name
 mfid0 (  278G) RAID-1      64k OPTIMAL Disabled
 mfid1 ( 1675G) RAID-10     64k OPTIMAL Disabled

Progressi saab vaadata Dell Perc

# mfiutil show progress
volume mfid1 Background Init: 1.20% complete, after 2078s finished in 47:25:44

samas on tekitatud raid1 volume juba kättesaadav ja kasutatav.