Erinevus lehekülje "LSI Raid" redaktsioonide vahel
Allikas: Kuutõrvaja
(Uus lehekülg: ''''Hp serverite raid kontroller''' ===FreeBSD=== mpt0: <LSILogic SAS/SATA Adapter> # mptutil show config mpt0 Configuration: 1 volumes, 2 drives volume 0 (136G) RAID-0 64...') |
(Erinevus puudub)
|
Redaktsioon: 21. juuni 2013, kell 10:59
Hp serverite raid kontroller
FreeBSD
mpt0: <LSILogic SAS/SATA Adapter>
# mptutil show config
mpt0 Configuration: 1 volumes, 2 drives
volume 0 (136G) RAID-0 64k OPTIMAL spans:
drive 1 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS
drive 0 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS
spare pools: 0
Või raid 1
# mptutil show config
mpt0 Configuration: 1 volumes, 2 drives
volume 0 (68G) RAID-1 OPTIMAL spans:
drive 1 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS
drive 0 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS
spare pools: 0
vaatame kettaid
# mptutil show drives mpt0 Physical Drives: 0 ( 68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS bus 0 id 3 1 ( 68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS bus 0 id 4
testime
root@testikas:/usr/home/jj # mptutil show volumes
mpt0 Volumes:
Id Size Level Stripe State Write-Cache Name
0 ( 136G) RAID-0 64k OPTIMAL Disabled
Debian
Kõigepealt mõned vajalikud sõltuvused
# aptitude install lib32gcc1 lib32stdc++6
Seejärel vaja tõmmata hp saidilt hpaccucli käsutööriista pakk
http://downloads.linux.hp.com/SDR/downloads/ProLiantSupportPack/Debian/pool/non-free/
Ning see paigaldada
# dpkg -i hpacucli_8.70-8.0.2-2_amd64.deb
kasutamine
# hpacucli ctrl all show config
Smart Array E200 in Slot 1 (sn: PA6C90P9SWN211)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (68.5 GB, RAID 0, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 73.5 GB, OK)
array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (558.7 GB, RAID 5, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)
Staatus
# hpacucli ctrl all show status Smart Array E200 in Slot 1 Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK
hpacucli> ctrl slot=0 pd 2:3 modify led=on ## To enable or Disable the LED hpacucli> ctrl slot=0 pd 2:3 modify led=off
Create LogicalDrive with RAID 5 using five drives:
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5
hpacucli> ctrl slot=0 ld 4 delete ## To Delete LogicalDrives