Sissejuhatus
TODO
Kasutamine
# ipssend GETCONFIG 1
Found 1 IBM ServeRAID controller(s).
Read configuration has been initiated for controller 1...
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller type : ServeRAID-4H
Controller FRU : 37L6892
Serial number : 001BP103
Part number : 37L6085
Actual BIOS version : 5.10.21
Firmware version : 5.10.21
Boot block version : 4.00.26
Device driver version : 7.12.05
Controller slot information : 5
Controller name : Null Config
SCSI channel description : 4 parallel SCSI wide
Initiator IDs (Channel/SCSI ID): 1/7 2/7 3/7 4/7
Maximum physical devices : 60
Defunct disk drive count : 0
Logical drives/Offline/Critical: 1/0/0
Readahead cache setting : Adaptive
Stripe-unit size : 16 KB
Rebuild rate (Low/Medium/High) : High
Hot-swap rebuild : Enabled
Data scrubbing : Enabled
Part of cluster (Yes/No) : No
Unattended mode (Yes/No) : No
Concurrent commands supported : 96
Configuration update count : 31
----------------------------------------------------------------------
Logical drive information
----------------------------------------------------------------------
Logical drive number 1
Status of logical drive : Okay (OKY)
RAID level : 1
Size (in MB) : 34715
Write cache status : Write back (WB)
Number of chunks : 2
Stripe-unit size : 16 KB
Access blocked : No
Part of array : A
Part of merge group : 207
Array A stripe order (Channel/SCSI ID) : 1,0 1,1
----------------------------------------------------------------------
Physical device information
----------------------------------------------------------------------
Channel #1:
Initiator at SCSI ID 7
Target on SCSI ID 0
Device is a Hard disk
SCSI ID : 0
PFA (Yes/No) : No
State : Online (ONL)
Size (in MB)/(in sectors): 34715/71096368
Device ID : IBM-ESXSST336752B8433ET0NNVN
FRU part number : 06P5352
Target on SCSI ID 1
Device is a Hard disk
SCSI ID : 1
PFA (Yes/No) : No
State : Online (ONL)
Size (in MB)/(in sectors): 34715/71096368
Device ID : IBM-ESXSST336752B8433ET0NQF3
FRU part number : 06P5352
Target on SCSI ID 8
Device is a Processor device
SCSI ID : 8
PFA (Yes/No) : No
State : Standby (SBY)
Size (in MB)/(in sectors): 0/0
Device ID : IBM St V1S20 000
Channel #2:
Initiator at SCSI ID 7
Channel #3:
Initiator at SCSI ID 7
Channel #4:
Initiator at SCSI ID 7
Command completed successfully.
Kasulikud materjalid
TODO