Erinevus lehekülje "LSI Raid" redaktsioonide vahel
(→Dell Perc FreeBSD) |
(→Dell Perc FreeBSD) |
||
159. rida: | 159. rida: | ||
7 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z2918395> SCSI-6 E1:S7 | 7 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z2918395> SCSI-6 E1:S7 | ||
− | Mfiutiliit lubab kuumvahetatavaid kettaid jooksvalt lisada raidi. | + | Mfiutiliit lubab kuumvahetatavaid kettaid jooksvalt lisada raidi. Näiteks oleme lisanud töötavale masinale kuus kõvaketast ja tahame tekitada neile raid10 seadistuse |
# mfiutil create raid10 E1:S2,E1:S3 E1:S4,E1:S5 E1:S6,E1:S7 | # mfiutil create raid10 E1:S2,E1:S3 E1:S4,E1:S5 E1:S6,E1:S7 |
Redaktsioon: 20. juuni 2014, kell 14:18
Hp serverite raid kontroller
FreeBSD
Seda kas draiver laetud saab kontrollida dmesgist
mpt0: <LSILogic SAS/SATA Adapter>
Utiliit info vaatamiseks on juba süsteemiga kaasas
# mptutil show config mpt0 Configuration: 1 volumes, 2 drives volume 0 (136G) RAID-0 64k OPTIMAL spans: drive 1 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS drive 0 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS spare pools: 0
Või raid 1
# mptutil show config mpt0 Configuration: 1 volumes, 2 drives volume 0 (68G) RAID-1 OPTIMAL spans: drive 1 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS drive 0 (68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS spare pools: 0
vaatame kettaid
# mptutil show drives mpt0 Physical Drives: 0 ( 68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS bus 0 id 3 1 ( 68G) ONLINE <SEAGATE ST973401LSUN72G 0556> SAS bus 0 id 4
testime
root@testikas:/usr/home/jj # mptutil show volumes mpt0 Volumes: Id Size Level Stripe State Write-Cache Name 0 ( 136G) RAID-0 64k OPTIMAL Disabled
Debian
Kõigepealt mõned vajalikud sõltuvused
# aptitude install lib32gcc1 lib32stdc++6
Seejärel vaja tõmmata hp saidilt hpaccucli käsutööriista pakk
http://downloads.linux.hp.com/SDR/downloads/ProLiantSupportPack/Debian/pool/non-free/
Ning see paigaldada
# dpkg -i hpacucli_8.70-8.0.2-2_amd64.deb
kasutamine
# hpacucli ctrl all show config
Smart Array E200 in Slot 1 (sn: PA6C90P9SWN211) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 73.5 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)
Staatus
# hpacucli ctrl all show status Smart Array E200 in Slot 1 Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK
hpacucli> ctrl slot=0 pd 2:3 modify led=on ## To enable or Disable the LED hpacucli> ctrl slot=0 pd 2:3 modify led=off
Create LogicalDrive with RAID 5 using five drives:
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5
hpacucli> ctrl slot=0 ld 4 delete ## To Delete LogicalDrives
Gentoo
# emerge sys-block/megacli,
* Upstream has implement a mandatory clickthrough EULA for distfile download * Please visit http://www.lsi.com/downloads/Public/MegaRAID%20Common%20Files/8.02.21_MegaCLI.zip * And place 8.02.21_MegaCLI.zip in /usr/portage/distfiles
# /opt/bin/MegaCli -PDList -aALL | grep Error
FreeBSD
Kui dmesgis on aga ciss draiver
ciss0: <HP Smart Array E200>
Smartmontooliga
# smartctl -iH -d cciss,0 /dev/ciss0
Viimase 2013 augusti alguse seisuga.
===> hpacucli-7.50_3 is marked as broken: currently does not work on amd64 (see PR ports/128288). *** Error code 1
Gentoo
# cciss_vol_status /dev/cciss/c0d0 /dev/cciss/c0d0: (Smart Array E200) RAID 1 Volume 0 status: OK.
Rohkem infot
# cciss_vol_status -s -V /dev/cciss/c0d0 Controller: Smart Array E200 Board ID: 0x3212103c Logical drives: 0 Running firmware: 1.78 ROM firmware: 1.78 /dev/cciss/c0d0: (Smart Array E200) RAID 1 Volume 0 status: OK. Physical drives: 4 connector 1I box 1 bay 1 HP DF0300B8053 3QP0CGM2000099130AAD HPD1 OK connector 1I box 1 bay 2 SEAGATE ST3300657SS 6SJ52A8C0000N2409BM5 0008 OK connector 1I box 1 bay 3 HP DF0300B8053 3QP0CFYM000099130C1T HPD1 OK connector 1I box 1 bay 4 HP DF0300B8053 3QP0CH9E00009913142T HPD1 OK
http://www.nico.schottelius.org/docs/freebsd-raid-monitoring/ palju väärt infot.
Dell Perc FreeBSD
mfi seade dmesgis
mfi0: <Dell PERC H700 Integrated> port 0xfc00-0xfcff mem 0xef0fc000-0xef0fffff,0xef040000-0xef07ffff irq 44 at device 0.0 on pci1
Kasutamiseks mfiutil
# mfiutil show drives mfi0 Physical Drives: 0 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVH6> SCSI-6 E1:S0 1 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVN6> SCSI-6 E1:S1 2 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CV7B> SCSI-6 E1:S2 3 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CTYF> SCSI-6 E1:S3 4 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVM4> SCSI-6 E1:S4 5 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z29182GP> SCSI-6 E1:S5 6 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z291CVHG> SCSI-6 E1:S6 7 ( 2795G) ONLINE <SEAGATE ST33000650SS RS0C serial=Z2918395> SCSI-6 E1:S7
Mfiutiliit lubab kuumvahetatavaid kettaid jooksvalt lisada raidi. Näiteks oleme lisanud töötavale masinale kuus kõvaketast ja tahame tekitada neile raid10 seadistuse
# mfiutil create raid10 E1:S2,E1:S3 E1:S4,E1:S5 E1:S6,E1:S7
Dmesgist saame vaadata, et kõik läks korrektselt ja seade tekkis
mfid1: <MFI Logical Disk> on mfi0 mfid1: 1715328MB (3512991744 sectors) RAID volume is optimal
Või siis küsida staatust kontrollerist endast
# mfiutil show volumes mfi0 Volumes: Id Size Level Stripe State Cache Name mfid0 ( 278G) RAID-1 64k OPTIMAL Disabled mfid1 ( 1675G) RAID-10 64k OPTIMAL Disabled
Progressi saab vaadata
# mfiutil show progress volume mfid1 Background Init: 1.20% complete, after 2078s finished in 47:25:44
samas on tekitatud raid1 volume juba kättesaadav ja kasutatav.