Sissejuhatus

Kõnealused seadmed paistavad lshw väljundis nt selliselt

# lshw
...
*-storage
     description: RAID bus controller
     product: Smart Array E200i (SAS Controller)
     vendor: Hewlett-Packard Company
     physical id: 8
     bus info: pci@0000:14:08.0
     version: 00
     width: 64 bits
     clock: 33MHz
     capabilities: storage pm msi pcix bus_master cap_list
     configuration: driver=cciss latency=64 module=cciss

Smartmontools

Smartmontools annab sarnast infot

# smartctl -a -d cciss,0 /dev/cciss/c0d0
smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

Device: HP       DH072ABAA6       Version: HPD2
Serial number: 3PD0CPWG00009745GXM6
Device type: disk
Transport protocol: SAS
Local Time is: Sun Jul 18 20:12:46 2010 EEST
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OK

Current Drive Temperature:     24 C
Drive Trip Temperature:        68 C
Elements in grown defect list: 0
Vendor (Seagate) cache information
  Blocks sent to initiator = 4216510770
  Blocks received from initiator = 3373165624
  Blocks read from cache and sent to initiator = 1563300222
  Number of read and write commands whose size <= segment size = 708950773
  Number of read and write commands whose size > segment size = 0

Error counter log:
           Errors Corrected by           Total   Correction     Gigabytes    Total
               ECC          rereads/    errors   algorithm      processed    uncorrected
           fast | delayed   rewrites  corrected  invocations   [10^9 bytes]  errors
read:          0        0         0         0          0          0.000           0
write:         0        0         0         0          0          0.000           0

Non-medium error count:        0
No self-tests have been logged
Long (extended) Self Test duration: 840 seconds [14.0 minutes]

HP Array Configuration Utility CLI for Linux